Parameters of aggregated units in VPP.
| | Parameters | Value |
| Gas turbine | 1/2/3 section cost curve slope/(¥/MW) | 282/318/353 | Maximum/minimum output power/(MW) | 5.67/2.5 | Maximum up/down climbing power/(MW) | 3/3 | Start cost/¥ | 212.0 | Fixed cost/¥ | 212.0 | Carbon emission intensity/(t/MW) | 0.42 |
| Carbon capture system | Capture efficiency | 0.90 | Solution reservoir maximum CO2 storage/t | 5.6 | Regeneration tower CO2 capture ability/(t/h) | 2 | Required power for unit CO2 capture/(t/MW) | 0.269 |
| Electric vehicle group | Capacity upper and lower limits/MW | 40/5 | Initial power reserve/MW | 25 | Charge/discharge efficiency | 0.9/0.9 | Maximum charge power/MW | 15 | Maximum discharge power/MW | 18 | Basic subsidized price/(¥/MW) | 70.7 | Dynamic subsidized coefficient | 0.1 |
| Interruptible load | Economic subsidy coefficient | 0.10 | 1/2/3 level load outage compensation price | 212/247/282 | Maximum load response ratio | 0.10 | Maximum load call at continuous time/MW | 2.5 |
|
|