Research Article

An Improved Direct Torque Control with an Advanced Broken-Bar Fault Diagnosis for Induction Motor Drives

Table 8

Comparative study between the proposed fault diagnosis strategy and existing methods in the literature.

Recent worksIM control strategiesApplied diagnostic methodsOperation modesLoad typeAutomatic fault detection
StationaryNonstationaryFullLow

Proposed workClosed-loop drive fuzzy neural DTCCombined HT-DWTYesYesYesYesANN detector
Reference [2]Open-loop driveDWT and HTYesYesYesNo
Reference [6]Closed-loop drive classical DTCFFTYesNoYesYesNo
Reference [10]Open-loop driveDWTYesYesYesANN detector
Reference [11]Closed-loop drive FOCFFTYesNoYesNo
Reference [14]Closed-loop drive IFOCHTYesNoYesYesANN detector
Reference [15]Closed-loop drive classical DTCFFT and DWTYesYesYesNo
Reference [30]Open-loop driveWavelet packetYesYesYesYesFuzzy logic detector