Research Article

Parameter Design of Half-Bridge Converter Series Y-Connection Microgrid Grid-Connected Filter Based on Improved PSO-LSSVM

Table 4

The LCL filter parameter designed by different methods and the corresponding parameter HCSY-MG system grid-connected current.

Lc (mH)Cf (μF)FundamentalTHD (%)fr (Hz)

Design method in this paper10.12010.421.133734
Traditional design method10.51010.41.72758
Graphical analysis method10.4610.421.753845
Optimized parameter method10.5510.41.833900
Multivariate system of equation method1.20.6109.81.382517