Research Article

Parameter Design of Half-Bridge Converter Series Y-Connection Microgrid Grid-Connected Filter Based on Improved PSO-LSSVM

Table 5

Sensitivity analysis of different D and d.

D, d1.1, 0.41.1, 0.61.1, 0.81.5, 0.41.5, 0.61.5, 0.81.7, 0.41.7, 0.61.7, 0.8
Training time (s)4.314.284.184.244.274.264.324.274.30
RMSE, MRE0.1965, 6.3760.1786, 5.92870.4106, 6.54870.1891, 6.14120.1703, 5.81690.2013, 6.21480.5162, 7.10470.1862, 6.10640.1807, 6.2303
, Cf (μF)0.102, 20.2080.146, 17.7120.217, 14.7840.145, 19.4810.124, 18.4260.134, 19.3860.267, 21.4200.162, 20.7140.126, 18.711
Fund., THD10.42, 1.13%10.15, 1.05%10.06, 1.12%10.13, 1.05%10.42, 1.13%10.13, 1.05%10.52, 2.11%10.27, 1.07%10.42, 1.13%