Research Article

Uninformative Biological Variability Elimination in Apple Soluble Solids Content Inspection by Using Fourier Transform Near-Infrared Spectroscopy Combined with Multivariate Analysis and Wavelength Selection Algorithm

Table 2

Prediction results for SSC by PLS with different pretreatments in calibration, validation, and prediction processes.

PretreatmentLVsCalibrationCross-validationPrediction

Raw140.95320.27640.90660.39030.87200.4197
S-G140.94290.30530.90520.39330.88630.4079
MSC140.96810.22820.91070.38160.84290.4795
SNV130.95130.28170.90500.39370.88340.4132
MeanN130.94760.29230.90810.38730.88160.4163
S-G and MSC140.94780.30670.91770.35650.89020.3998
S-G and MeanN140.94740.30630.90890.37560.88830.4044
MSC and MeanN140.96810.22820.91070.38160.84290.4795
MSC and SNV130.95140.28170.90500.39040.88340.4131