Research Article

Development of an Efficient Analytical Method for the Extraction and Analysis of Biocide Contents from the Textile Test Specimens on LC-DAD

Table 2

Results of robustness study on MIT.

ConditionAssay, %Retention time, minutesNumber of theoretical platesTailingResolution

0.4% citric acid: methanol (50 : 50)100.182.506183400.9610.36
0.4% citric acid: methanol (55 : 45)99.422.485180761.186.05
0.4% citric acid: methanol (45 : 55)100.603.365188971.0912.28
Flow rate, 1.1 mL min−199.782.455182251.069.85
Flow rate, 0.9 mL min−1100.332.535174321.2010.70
Column oven temperature 33100.402.475162341.349.65
Column oven temperature 27100.382.511189541.0810.26