Research Article

Determination of the Contents of Antioxidants and Their Degradation Products in Sodium Chloride Injection for Blood Transfusion

Table 4

The LOD, LOQ, and linearity.

AnalytesLOD (μg/mL)LOQ (μg/mL)Calibration range (μg/mL)Linearityr

BHT-OH0.0500.1390.22~43.46y = 5,930.9470 x + 1,825.79230.9996
BHT-COOH0.0150.0580.11~45.28y = 17,708.1278 x − 1,646.53491.0000
13100.0570.2380.49~39.14y = 3,920.6502 x − 598.54091.0000
BHT-CHO0.0110.0310.10~41.77y = 33,938.8492 x − 5,298.70720.9999
BHT-Q0.1510.3930.48~38.02y = 2,292.7295 x − 1,549.65310.9994
DBP0.0420.1160.19~38.38y = 7,141.6319 x − 596.67041.0000
BHT0.0480.1330.23~46.80y = 5,549.7995 x − 577.96721.0000
31140.0830.2290.51~40.72y = 3,338.2474 x − 524.05590.9999
10100.0540.1750.20~40.08y = 3,775.4647 x − 298.19731.0000
13300.0540.1230.20~39.82y = 5,433.0830 x − 415.69401.0000
10760.0750.3260.53~42.56y = 2,093.7651 x − 303.78111.0000
1680.1220.3710.52~41.71y = 2,443.9582 x − 555.04951.0000