Research Article

Contribution to the Detection of Poor Quality Sildenafil Drugs in Burkina Faso Using High-Performance Thin-Layer Chromatography

Table 2

Optimized operating conditions for the determination of sildenafil.

ParametersValue/selected characteristic(s)

Mobile phaseMethylene chloride-methanol (9 : 1, v/v)
Solubilization and dilution solventMethanol
PlatesMerck TLC silica gel F254 20 × 10 cm
Deposited volume on the plate5 μL
Width of the deposit strip7.4 mm
Length between deposits9.4 mm
Distance from the deposition line to the edges of the plate (abscissa and ordinate)8 and 10 mm
Development distance on plate70 mm
Development modeLinear ascending mode
Saturation time of mobile phase30 min
Deposit flow15 µL/s
Deposit modeSpray
Gas for sample applicationNitrogen
Detection wavelength305 nm