Research Article

Decoupling Control Strategy of IPT System Based on Optimal Efficiency Load Tracking

Table 3

System simulation parameters.

ParametersValue

DC voltage 750
Maximum power 100
Frequency f/kHz50
Primary coil self-induction 160,8
Secondary coil self-induction 91
Primary coil self-resistance 13,10
Secondary coil self-resistance 3,12
Primary compensation capacitance 63,07
Secondary compensation capacitance 111,45
Load resistance 5
Mutual inductance 4,5-9,0