Research Article
Compressive Strength Gain Behavior and Prediction of Cement-Stabilized Macadam at Low Temperature Curing
Table 6
The compressive strength of tested and predicted outdoor curing.
| Days | 7 d | 8 d | 9 d | 10 d | 11 d | 12 d | 13 d |
| Maturity (°C·h) | 1690 | 1946 | 2200 | 2462 | 2719 | 2979 | 3246 | Tested value (MPa) | 2.200 | 2.500 | 2.700 | 2.900 | 3.100 | 3.300 | 3.500 | Predicted value (MPa) | 2.205 | 2.478 | 2.715 | 2.933 | 3.125 | 3.302 | 3.468 |
|
|