Journal of Chemistry / 2013 / Article / Tab 6 / Research Article
Liquid Anion Exchange Chromatographic Extraction and Separation of Platinum(IV) with n-Octylaniline as a Metallurgical Reagent: Analysis of Real Samples Table 6 Separation of platinum(IV) from binary mixtures.
Amount of metal ion, (
g) Mass taken, (
g)
Average (%) recovery* Chromogenic ligand Reference no. Pt(IV) Ir(III) 150 100 99.5 99.4 Stannous chloride-hydrobromic acid [44 ] Pt(IV) Rh(III)a 150 300 99.7 99.2 Stannous chloride-KI [44 ] Pt(IV) Pd(II)a 150 200 99.8 99.4 4′-ChloroPTPT [47 ] Pt(IV) Ru(III) 150 200 99.2 98.9 4′-ChloroPTPT [47 ] Pt(IV) Au(III) 150 200 99.8 99.1 SnCl2 [44 ] Pt(IV) Se(IV) 150 200 99.7 99.0 4′-ChloroPTPT [48 ] Pt(IV) Te(IV) 150 200 99.8 98.9 4′-ChloroPTPT [49 ] Pt(IV) Os(VIII) 150 200 99.4 99.0 Thiourea [44 ] Pt(IV) Fe(III) 150 500 99.4 98.7 Thiocyanate [44 ] Pt(IV) Cu(II) 150 1000 99.0 98.6 4′-ChloroPTPT [50 ] Pt(IV) Ni(II) 150 1000 99.0 97.9 DMG [46 ] Pt(IV) Co(II) 150 500 99.9 97.8 Thiocyanate [44 ]
Masked with 20 mg tartrate.
*Average of five determinations.