Research Article
Thionine-Bromate as a New Reaction System for Kinetic Spectrophotometric Determination of Hydrazine in Cooling Tower Water Samples
Table 3
The recovery results on the determination of hydrazine in the different water samples using the proposed method and the standard ASTM method.
| | Hydrazine (g mL−1) | Sample | Proposed method | ASTM method | Statistical test | | Added | Founda | Recovery (%) | Added | Founda | Recovery (%) | testb |
| Distilled water | 1.0 | 1.01 ± 0.01 | 102.0 | 1.0 | 0.99 ± 0.01 | 99.0 | 3.40 | 5.0 | 4.98 ± 0.05 | 99.6 | 5.0 | 5.01 ± 0.03 | 100.2 | 1.04 |
| Drinking water | 1.0 | 0.99 ± 0.03 | 99.0 | 1.0 | 1.01 ± 0.01 | 101.0 | 1.15 | 5.0 | 5.03 ± 0.04 | 100.6 | 5.0 | 4.98 ± 0.05 | 99.6 | 2.16 |
| | — | 2.12 ± 0.02 | | — | 2.09 ± 0.02 | | 2.59 | Cooling tower water (1) | 1.0 | 3.14 ± 0.03 | 100.6 | 1.0 | 3.08 ± 0.03 | 98.7 | 3.46 | 5.0 | 7.05 ± 0.08 | 99.0 | 5.0 | 7.15 ± 0.08 | 102.4 | 2.16 | | 15.0 | 17.19 ± 0.15 | 100.4 | 15.0 | 17.38 ± 0.18 | 101.7 | 2.19 |
| | — | 2.25 ± 0.02 | | — | 2.27 ± 0.02 | | 1.73 | Cooling tower water (2) | 10.0 | 12.19 ± 0.11 | 99.5 | 10.0 | 12.28 ± 0.12 | 100.9 | 1.42 | | 20.0 | 22.31 ± 0.21 | 100.3 | 20.0 | 22.08 ± 0.19 | 99.6 | 1.89 |
|
|
aMean ± standard deviation ().
bTabulated -value for three replicate determinations at (0.95) is 4.30.
|