Research Article

Thionine-Bromate as a New Reaction System for Kinetic Spectrophotometric Determination of Hydrazine in Cooling Tower Water Samples

Table 3

The recovery results on the determination of hydrazine in the different water samples using the proposed method and the standard ASTM method.

Hydrazine ( g mL−1)
SampleProposed methodASTM methodStatistical test
AddedFoundaRecovery (%)AddedFoundaRecovery (%) testb

Distilled water1.01.01 ± 0.01102.01.00.99 ± 0.0199.03.40
5.04.98 ± 0.0599.65.05.01 ± 0.03100.21.04

Drinking water1.00.99 ± 0.0399.01.01.01 ± 0.01101.01.15
5.05.03 ± 0.04100.65.04.98 ± 0.0599.62.16

2.12 ± 0.022.09 ± 0.022.59
Cooling tower water (1)1.03.14 ± 0.03100.61.03.08 ± 0.0398.73.46
5.07.05 ± 0.0899.05.07.15 ± 0.08102.42.16
15.017.19 ± 0.15100.415.017.38 ± 0.18101.72.19

2.25 ± 0.022.27 ± 0.021.73
Cooling tower water (2)10.012.19 ± 0.1199.510.012.28 ± 0.12100.91.42
20.022.31 ± 0.21 100.320.022.08 ± 0.1999.61.89

aMean ± standard deviation ( ).
bTabulated -value for three replicate determinations at (0.95) is 4.30.