Table 1

Intensity and wavelength of Ar I and Ar II lines at 5 kV.

LinesWavelength (nm)Transition probability (S−1)Statistical weightEnergy (eV)Intensity(au) at 5 kV

Ar I696.054Apq = 6.39 × 106 = 5Ep = 11.564I1 = 16778
Ar I750.28Ars = 4.02 × 107 = 3Er = 11.636I2 = 8954.44
Ar II314.82Axy = 5.20 × 107 = 6Ex = 19.249I3 = 6211.09
Ar II379.81Auv = 1.05 × 106 = 8Eu = 16.797I4 = 8201.75