Research Article
Microwave-Assisted Digestion Using Dilute Nitric Acid and Hydrogen Peroxide for Multielement Determination in Wheat Flour by ICP-MS
Table 2
Experiments and multiple response (MR) parameters from full factorial design 24.
| Experiment no | Volume of mixture | Temperature (°C) | Time (min) | Amount of sample | MR |
| 1 | 8 | 200 | 15 | 0.3 | 6.44791 | 2 | 8 | 200 | 20 | 0.3 | 6.12712 | 3 | 8 | 200 | 15 | 0.5 | 7.57222 | 4 | 8 | 200 | 20 | 0.5 | 6.14336 | 5 | 12 | 200 | 15 | 0.3 | 6.69651 | 6 | 12 | 200 | 20 | 0.3 | 6.51015 | 7 | 12 | 200 | 15 | 0.5 | 6.91626 | 8 | 12 | 200 | 20 | 0.5 | 5.71776 | 9 | 8 | 210 | 15 | 0.3 | 8.36120 | 10 | 8 | 210 | 20 | 0.3 | 7.18961 | 11 | 8 | 210 | 15 | 0.5 | 6.31110 | 12 | 8 | 210 | 20 | 0.5 | 7.06297 | 13 | 12 | 210 | 15 | 0.3 | 8.24488 | 14 | 12 | 210 | 20 | 0.3 | 7.28224 | 15 | 12 | 210 | 15 | 0.5 | 9.72882 | 16 | 12 | 210 | 20 | 0.5 | 7.79609 |
|
|