Barkman and Abrams blocking criteria.

Particle size rangeDamage result

The rock pore size is less than 3 times the solid phase particle sizeSurface bridging to form a filter cake
3 times the particle size of the solid phase < rock pore diameter < 10 times the particle size of the solid phaseShallow plugging near wellbore