Performance of A/O system under different gas/water ratios.

Gas/water ratioChemical oxygen demand (COD)Ammonium (NH4+-N)Total nitrogen (TN)Total phosphorus (TP)
Average influent value (mg/L)Average effluent value (mg/L)Average removal efficiency value (%)Average influent value (mg/L)Average effluent value (mg/L)Average removal efficiency value (%)Average influent value (mg/L)Average effluent value (mg/L)Average removal efficiency value (%)Average influent value (mg/L)Average effluent value (mg/L)Average removal efficiency value (%)

5 : 1307.2325.9091.2740.744.3488.7746.7420.5055.464.101.0173.05
7 : 1313.3312.9895.5636.450.8797.2744.609.0878.673.860.5784.49
10 : 1320.7312.1096.1638.750.3698.9840.7320.1549.462.741.5242.32
15 : 1319.938.5397.0837.170.2599.2443.4322.0348.443.682.4632.47
20 : 1292.676.9797.5146.530.2099.5652.0728.4045.333.572.6525.02