Research Article
Study on Optimization of Pump Shaft Transmission System of Plastic Centrifugal Pump
Table 13
Comparison of schemes before and after pump shaft optimization.
| Parameter | Initial scheme | Optimum proposal | Improvement effect |
| Deflection (mm) | 0.018616 | 0.00887 | Reduce by 52.35% | Quality (kg) | 4.808048 | 4.415914 | Reduce by 8.16% | First order critical speed (r/min) | 2906.54 | 4149.72 | Increase by 42.77% |
|
|