Comparison of schemes before and after pump shaft optimization.

ParameterInitial schemeOptimum proposalImprovement effect

Deflection (mm)0.0186160.00887Reduce by 52.35%
Quality (kg)4.8080484.415914Reduce by 8.16%
First order critical speed (r/min)2906.544149.72Increase by 42.77%