Research Article

Modelling and Output Power Estimation of a Combined Gas Plant and a Combined Cycle Plant Using an Artificial Neural Network Approach

Table 2

Sample real data of the combined cycle power plant [55].

SampleAT (input) (°C)V (input) (cmHg)AP (input) (mbar)RH (input)EP (output) (MW)

19.3440.771010.9490.01490.48
223.6459.491011.4274.23445.75
329.7456.911007.1541.91439.76
419.0749.691007.2276.79452.09
511.8440.661017.1297.23464.43
……………………
956516.6549.691014.0191.04460.03
956613.1939.181023.6766.78469.62
956731.3274.331012.9236.48429.57
956824.4869.451013.8662.39435.74