Research Article

Analysis of the Consecutive Mean Excision Algorithms

Table 1

The values of 𝛼 1 and SNR [dB] when signal detection via the CME algorithm is impossible with different values of 𝑇 and 𝛽 1 . The signal has only one lobe. Note that SNR is defined per total bandwidth.

𝛽 1 = 0 . 0 5 𝛽 1 = 0 . 1 𝛽 1 = 0 . 2 𝛽 1 = 0 . 3 𝛽 1 = 0 . 4
𝑇 𝛼 1 (SNR [dB]) 𝛼 1 (SNR [dB]) 𝛼 1 (SNR [dB]) 𝛼 1 (SNR [dB]) 𝛼 1 (SNR [dB])

2.3026<1.472 (−9 dB)<1.692 (−6 dB)<2.415 (−2 dB)<4.213 (2 dB)<16.497 (8 dB)
4.6052<4.684 (−5 dB)<6.683 (−1 dB)<45.659 (10 dB) —*—*
6.9078<9.025 (−3 dB)<19.106 (3 dB) —* —* —*

*Detection is not possible.