Research Article

Analysis of the Consecutive Mean Excision Algorithms

Table 2

The values of 𝛼 1 and SNR [dB] when signal detection via the FCME algorithm is impossible with different values of 𝑇 and 𝛽 1 . The signal has only one lobe. Note that SNR is defined per total bandwidth.

𝛽 1 = 0 . 0 5 𝛽 1 = 0 . 1 𝛽 1 = 0 . 2 𝛽 1 = 0 . 3 𝛽 1 = 0 . 4
𝑇 𝛼 1 (SNR [dB]) 𝛼 1 (SNR [dB]) 𝛼 1 (SNR [dB]) 𝛼 1 (SNR [dB]) 𝛼 1 (SNR [dB])

2.3026<1.303 (−9 dB)<1.303 (−6 dB)<1.303 (−3 dB)<1.303 (−2 dB)<1.303 (0 dB)
4.6052<3.605 (−6 dB)<3.605 (−3 dB)<3.605 (0 dB)<3.605 (2 dB)<3.605 (3 dB)
6.9078<5.908 (−5 dB)<5.908 (−2 dB)<5.908 (1 dB)<5.908 (3 dB)<5.908 (4 dB)