Research Article
Application of Fuzzy Control in a Photovoltaic Grid-Connected Inverter
Figure 11
Grid-connected output current and load current with different load characteristics.
| (a) Waveform of conventional deadbeat control with 500 W resistive load + 300 W capacitive load |
| (b) Waveform of fuzzy control method with 500 W resistive load + 300 W capacitive load |
| (c) Waveform of conventional deadbeat control with 100 W capacitive load + 150 W inductive load + 500 W resistive load |
| (d) Waveform of fuzzy control method with 100 W capacitive load + 150 W inductive load + 500 W resistive load |