Research Article
Research on Modelling and Stability Characteristics of Electric Traffic Energy System Based on ZVS-DAB Converter
Table 1
Performance comparison between DAB converter and LLC resonant converter.
| | Parameter | DAB | LLC |
| | External capacitor | No (small volume) | Yes (large volume) | | Voltage controllability | High | Low | | Total ZVS | Yes | Yes | | Secondary side ZCS | No | Yes | | Parallel current-sharing | Easy | Difficult | | Antimagnetic saturation | Software | Hardware | | Current stress | Lower | Higher | | Suppression of DC second harmonic | Yes | No | | Control points | PI voltage closed loop, antimagnetic saturation | Power switching, load sharing |
|
|