Research Article
A Flexible Wearable Thermography System Based on Bioheat Microsensors Network for Early Breast Cancer Detection: IoT Technology
Table 3
Comparative results of the abnormal breast phantom.
| Tumor location | Nipple | LOQ | UIQ |
| Bioheat microsensors nearest to tumor | RBrW1, RBrE1, RBrS1, and RBrN1 | RBrSW1 and RBrSW2 | RBrNE1 and RBrNE2 | Thermal gradient measured by COMSOL multiphysics (°C) | 24.44 | 24.40 | 24.28 | Thermal gradient measured by the thermal system test bench (°C) | 24.45 | 24.51 | 24.32 | Errors (°C) | 0.01 | 0.11 | 0.04 |
|
|