Research Article

Comprehensive Analysis of ZVS Operation Range and Deadband Conditions of a Dual H-Bridge Bidirectional DC-DC Converter with Phase Shift Control

Figure 9

(a) Dependency of the output power on operating phase shift and leakage inductance for DAB converter. (b) A dependency of the output power on operating phase shift frequency for DAB converter. (c) Output power characterization A versus phase shift ratio of the DAB. (d) Effect of phase shit ratio on the current stress under full load condition.
(a)
(b)
(c)
(d)