Research Article

A Novel Subspace Decomposition with Rotational Invariance Technique to Estimate Low-Frequency Oscillatory Modes of the Power Grid

Table 4

Statistical analysis for RMP, QR-TLS-ESPRIT, KLT-TLS-ESPRIT, data-SSI, and MKLT-TLS-ESPRIT at SNR = 30 dB.

SNR = 30 dBFrequency (Hz)Attenuation factor
Std. dev.MeanVarianceStd. dev.MeanVariance

RMP9.76431.50989.53411.0328−0.04031.0667
QR-TLS-ESPRIT6.16311.49513.79832.8643−0.19148.2042
KLT-TLS-ESPRIT6.05311.50143.66403.6481−0.12541.3308
Data-SSI9.62891.49715.82001.1462−0.09151.3137