Research Article

Simultaneous Determination of B1, B2, B3, B6, B9, and B12 Vitamins in Premix and Fortified Flour Using HPLC/DAD: Effect of Detection Wavelength

Table 3

System suitability test results for the HPLC method for determination of B vitamins (9 injections of aqueous standard solution containing 5 mg/L).

VitaminWavelength (nm)RT (min)a% RSD of RTPA% RSD of PACapacity factor (K)Selectivity (α)Resolution (RS)Tailing factor (TF)TP

B12654.371.402.650.790.731.323.411.2312020
2804.321.451.131.550.721.333.451.2311896

B32654.961.312.490.630.971.549.961.4110815
2804.921.520.242.300.951.5710.721.2910940

B62656.290.390.672.431.501.4621.651.85117192
2806.290.392.161.371.501.4622.151.21130915

B92658.020.241.421.382.181.053.081.15137022
2808.020.242.10.922.181.053.041.15143606
3618.020.230.462.442.181.053.061.16142637

B122658.300.180.940.742.291.168.051.11103467
2808.300.181.060.892.291.167.941.1299293
3618.300.211.911.452.291.168.031.11107767

B22659.230.375.471.332.661.1278402
2809.230.373.652.352.661.1280602
3619.231.371.682.542.651.1180869

a The retention time of unretained peak is 2.52 min. RT: retention time, RSD: relative standard deviation, PA: peak area, and TP: theoretical plates.