Pseudosteady state productivity indexes for Example 2.

Square reservoirInscribed circular reservoir
(ft)PI (STB/day/psi)R0 = Re (ft)PI (STB/day/psi)

1003.909003.45
2004.038003.78
3004.157004.02
4004.276004.20
5004.375004.36
6004.454004.48
7004.523004.58
8004.572004.64
9004.601004.69
1,0004.6104.70