Statistical comparison of the parameters between our methodology and manual analyses by analyst (ground truth).
| | Our method (first measure) mean (CI) | Ground truth (second measure) mean (CI) | Our method (first measure) median (IQR) | Ground truth (second measure) median (IQR) | Difference | Relative difference | ICC (95% CI) | ICC value |
| Lumen area | 5.99 (5.83–6.14) | 5.89 (5.74–6.04) | 6.45 (4.72–7.67) | 6.29 (4.67–7.50) | 0.10 (0.06–0.13) | −1.12% (−1.55% to −0.68%) | 0.97 (0.97–0.98) | <0.0001 | Mean lumen diameter | 2.72 (2.68–2.76) | 2.68 (2.64–2.72) | 2.88 (2.41–3.13) | 2.82 (2.43–3.09) | 0.03 (0.02–0.04) | −1.15% (−1.48% to −0.83%) | 0.96 (0.95–0.97) | <0.0001 | Minimal lumen diameter | 2.52 (2.48–2.56) | 2.49 (2.45–2.53) | 2.64 (2.18–2.96) | 2.61 (2.10–2.93) | 0.03 (0.02–0.03) | −1.11% (−1.44% to −0.78%) | 0.98 (0.98–0.98) | <0.0001 | Maximal lumen diameter | 2.91 (2.87–2.96) | 2.88 (2.84–2.92) | 3.07 (2.54–3.30) | 3.01 (2.58–3.25) | 0.04 (0.02–0.05) | −0.81% (−1.23% to −0.39%) | 0.91 (0.89–0.92) | <0.0001 |
|
|