Journal of Healthcare Engineering / 2020 / Article / Tab 2 / Research Article
Application of the Lomb-Scargle Periodogram to InvestigateHeart Rate Variability during Haemodialysis Table 2 Comparison of results obtained from five different methods of RR editing (using 100 simulations with different random noise profiles) and asymmetric selection criteria (+32.5% or −24.5%).
Method 1 Method 2 Method 3 (replacement) Method 4 Method 5 “Baseline” “Rules” Cubic spline Linear Mean OUGP EMD Mean RR (sec) 0.94 ± 0.01 0.93 ± 0.01 0.94 ± 0.01 0.94 ± 0.01 0.94 ± 0.01 0.91 ± 0.01 0.92 ± 0.01 Range RR (sec) 0.64 0.72 0.74 0.73 0.73 0.59 0.81 LF (nu) 0.39 ± 0.04 0.41 ± 0.05 0.43 ± 0.05 0.44 ± 0.05 0.38 ± 0.04 0.43 ± 0.04 0.32 ± 0.04 HF (nu) 0.51 ± 0.04 0.48 ± 0.05 0.45 ± 0.04 0.43 ± 0.04 0.52 ± 0.04 0.55 ± 0.04 0.66 ± 0.04 LF/HF 0.77 ± 0.13 0.87 ± 0.18 0.97 ± 0.18 1.05 ± 0.19 0.75 ± 0.13 0.8 ± 0.13 0.48 ± 0.09 Total power (dB) −19.08 ± 0.38 −19.49 ± 0.45 −18.42 ± 0.4 −18.87 ± 0.4 −19.59 ± 0.39 −19.57 ± 0.47 −17.97 ± 0.45 LF location (mHz) 95.0 ± 1.52 91.8 ± 15.38 72.5 ± 30.38 68.3 ± 31.28 91.0 ± 24.4 96.0 ± 0.92 94.9 ± 0.31 HF location (mHz) 273.1 ± 17.96 257.2 ± 53.17 156.3 ± 81.28 140.8 ± 74.37 248.2 ± 56.28 263.1 ± 46.44 275.0 ± 0.29 (A l /A h )2 1.15 ± 0.52 1.72 ± 0.78 1.33 ± 0.91 1.29 ± 1 1.52 ± 0.75 1.97 ± 0.89 0.75 ± 0.29 % of LF peak > FAP 10% 97 93 78 80 92 100 99 % of HF peak > FAP 10% 97 89 81 84 79 97 100
Data are presented as mean ± std.