Research Article

[Retracted] Diagnosis and Etiological Analysis of Gastroesophageal Reflux Disease by Gastric Filling Ultrasound and GerdQ Scale

Table 4

ROC curve analysis of the four detection methods.

Test result variableAUCStandard error95% confidence intervalCutoffYouden’ indexSensitivitySpecificity
Lower limiting valueHigher limiting value

His angel0.9570.019<0.0010.9200.99358.1350.85693.5092.10
Length of abdominal esophagus0.8610.038<0.0010.7870.9343.2950.61698.4063.20
Ultrasonic combination parameter0.9960.005<0.0010.9871.000−4.40700.98498.40100.00
GerdQ score0.9310.025<0.0010.8820.9807.310.82490.3092.10

Note. The parameters of ultrasonic combination are His angle and abdominal esophagus length, and its formula is calculated as ultrasonic combination parameter = abdominal esophagus length + 0.360/2.791 His angle.