Research Article
Artificial Intelligence Analysis of EEG Amplitude in Intensive Heart Care
Table 1
TWIN-SVM and common recognition algorithms results.
| | Testing objects | PSO-LS-TWIN-SVM | LDA | BP | PNN |
| | 1 | 88.19 | 87.24 | 72.43 | 83.45 | | 2 | 64.35 | 57.32 | 62.34 | 61.35 | | 3 | 93.42 | 91.34 | 97.53 | 88.24 | | 4 | 65.34 | 63.24 | 71.34 | 70.12 | | 5 | 76.35 | 54.87 | 52.34 | 50.35 | | 6 | 67.34 | 70.23 | 74.45 | 65.24 | | 7 | 75.23 | 70.43 | 74.14 | 58.33 | | 8 | 88.89 | 83.25 | 87.24 | 91.34 | | 9 | 78.34 | 73.42 | 76.35 | 73.24 | | 10 | 67.24 | 70.78 | 66.24 | 70.43 | | Mean | 76.47 | 72.21 | 73.44 | 71.21 | | SE | 11.24 | 13.34 | 12.32 | 16.31 |
|
|