Research Article

[Retracted] Dose Prediction Models Based on Geometric and Plan Optimization Parameter for Adjuvant Radiotherapy Planning Design in Cervical Cancer Radiotherapy

Table 5

Univariate and multivariate linear regression significance scores for prediction of the rectum dose.

VariablesOutcome valueR2 valueR2
variable(univariate)(univariate)(multivariate)(multivariate)

PTV volumeV300.0570.092NN
V350.1510.039NN
V400.3780.028NN
D2cc0.7720.033NN

Rectal volumeV300.2350.016NN
V350.1970.025NN
V400.2120.021NN
D2cc0.0360.117NN

OV of rectumV300.2350.016NN
V350.0680.082NN
V400.0170.1560.2660.993
D2cc<0.0010.543<0.0010.543

OP of rectumV300.0020.26<0.0010.997
V35<0.0010.454<0.0010.995
V40<0.0010.612<0.0010.993
D2cc0.0020.272NN

V30 of NOS rectumV30<0.0010.955<0.0010.997
V35 of NOS rectumV35<0.0010.919<0.0010.995
V40 of NOS rectumV40<0.0010.843<0.0010.993
D2cc of NOS rectumD2cc0.0080.1960.8110.527

āˆ—OV: the volume of the overlap of the OAR with the PTV; OP: the percentage volume of the overlap of the OAR; NOS rectum: the structure of the rectum outside the PTV; N indicated that this parameter did not participate in the multivariate linear regression analysis.