Research Article
Premature Ventricular Contraction Recognition Based on a Deep Learning Approach
Table 5
Comparison between the suggested network and other baseline models on MIT-BIH arrhythmia database.
| Method | PPV (mean) | Recall (mean) | F-score (mean) |
| Allami et al. [20] | 97.8 | 98.7 | 98.2 | Pierleoni et al. [44] | 86 | 87 | 86.5 | Xie et al. [31] | 95.4 | 97.8 | 96.6 | Yu et al. [6] | 98.1 | 97.2 | 97.6 | Our approach | 98.6 | 99.2 | 98.9 |
|
|