Research Article

An ROI Extraction Method of Finger Vein Images Based on Large Receptive Field Gradient Operator for Accurate Localization of Joint Cavity

Table 4

EERs calculated by different ROI extraction methods.

FeatureROIMMCBNU_6000 (%)UTFVP (%)FV-USM (%)

Maximum curvatureYao’s method6.331.398.85
Single sliding window method6.764.245.89
Fixed window4.973.292.47
Dual-sliding windows5.774.516.38
Single-line accumulation7.193.594.50
Proposed method4.912.772.81

Repeated line trackingYao’s method4.261.7413.22
Single sliding window method3.761.353.59
Fixed window2.381.041.52
Dual-sliding windows3.221.534.84
Single-line accumulation3.951.123.34
Proposed method3.730.971.69