Research Article

[Retracted] Automated Detection and Segmentation of Exudates for the Screening of Background Retinopathy

Table 1

Performance evaluation of the proposed method at exudates-based and image-based levels.

AuthorDatasetsNumber of retinal fundus images usedExudates-based assessment (%)Image-based assessment (%)
SensitivitySpecificityAccuracySensitivitySpecificityAccuracy

Reza et al. [36] STARE
DRIVE
2094.3%100%----------------
Yazid et al. [8]STARE1597.8%99%----------------
Jaya et al. [37]Clinical20094.1%90%93%------------
Welfer et al. [11]DIARETDB18970.4%98.84%----------------
Niemeijer et al. [15]Clinical300------------95%86%----
Youssef et al. [38]Clinical7------------80%100%----
Lahmiri et al. [39]STARE45------------100%100%100%
Osareh et al. [14]Clinical14293%94.1%----95%88.9%----
Gracia et al. [40]Clinical11788.08%--------100%83.95%93.53%
Sanchez et al. [7]Clinical8090.2%--------100%90%----
Harangi et al. [41]DIARETDB18963%85%----89%--------
Kaur and Mittal [35]Multiple datasets130788.85%96.15%93.46%94.62%98.64%96.74%
Khojasteh et al. [42]DIARETDB e-Ophtha284------------96%98%98%
Kusakunniran et al. [43]DIARETDB1 e-Ophtha EX28456.4%99.9%99.8%------------
Balasubramanian et al. [44]RIM-ONE15--------------------97.8%
Proposed methodClinical64995.67%98.23%97.24%97.45%99.76%98.65%
MESSIDOR40091.21%96.21%94.12%93.24%97.49%97.43%
e-Ophtha EX7293.47%94.57%93.47%93.87%94.28%93.82%
DiaretDB17092.47%98.84%96.78%96.78%97.28%99.02%
STARE8695.38%96.98%96.12%94.98%93.28%97.98%
DRIVE3098.89%97.23%98.23%95.23%95.23%97.32%
 OVERALL130793.44%97.22%95.68%95.345%98.63%98.04%