Evaluation of Four Rapid Tests for Detection of Hepatitis B Surface Antigen in Ivory Coast
Table 3
Results observed with the Monolisa test for samples giving false results with any of the rapid diagnosis tests.
Identity
OD/TVa with Monolisa AgHBs Ultra®
Status HBsAgb
Results of rapid diagnosis tests
Determine™ HBsAg
SD Bioline HBsAg WB®
Standard Q HBsAg®
Vikia HBsAg®
7402926
33,7
Positive
Positive
Positive
Negative
Positive
9449856
43,8
Positive
Positive
Positive
Negative
Positive
1457809
32,0
Positive
Positive
Positive
Negative
Positive
9441806
41,2
Positive
Positive
Positive
Negative
Positive
ETR 036B/18
31,9
Positive
Positive
Positive
Negative
Positive
ETR 037B/18
33,1
Positive
Positive
Negative
Negative
Positive
ETR 045B/18
34,0
Positive
Positive
Positive
Negative
Positive
ETR 048B/18
34,6
Positive
Positive
Positive
Negative
Positive
ETR 052B/18
27,9
Positive
Positive
Positive
Negative
Positive
ETR 164B/18
21,1
Positive
Positive
Positive
Negative
Positive
C-019
32.3
Positive
Positive
Positive
Negative
Positive
C-345
32.3
Positive
Positive
Negative
Negative
Positive
S-262
29.5
Positive
Positive
Positive
Positive
Positive
S-169
23.6
Positive
Positive
Positive
Negative
Positive
YOP HGE 022
32.9
Positive
Positive
Negative
Negative
Positive
H-3569
32.3
Positive
Positive
Positive
Negative
Positive
HGT HGE 011
12,5
Positive
Positive
Positive
Negative
Positive
ETR 144B/18
1,3
Negative
Negative
Positive
Positive
Negative
aRatio of the sample optical density (OD) to the threshold value (TV), as calculated by Monolisa AgHBs Ultra®. Samples with OD/TV values greater than or equal to 1.00 are considered reactive. b Determined with two EIA tests: Dia.Pro HBsAg® one version ULTRA for detection of HBsAg; positive samples were confirmed using Monolisa™ HBsAg ULTRA Confirmation test.