Results observed with the Monolisa test for samples giving false results with any of the rapid diagnosis tests.

IdentityOD/TVa with Monolisa AgHBs Ultra®Status HBsAgbResults of rapid diagnosis tests
Determine™ HBsAgSD Bioline HBsAg WB®Standard Q HBsAg®Vikia HBsAg®

740292633,7PositivePositivePositiveNegativePositive
944985643,8PositivePositivePositiveNegativePositive
145780932,0PositivePositivePositiveNegativePositive
944180641,2PositivePositivePositiveNegativePositive
ETR 036B/1831,9PositivePositivePositiveNegativePositive
ETR 037B/1833,1PositivePositiveNegativeNegativePositive
ETR 045B/1834,0PositivePositivePositiveNegativePositive
ETR 048B/1834,6PositivePositivePositiveNegativePositive
ETR 052B/1827,9PositivePositivePositiveNegativePositive
ETR 164B/1821,1PositivePositivePositiveNegativePositive
C-01932.3PositivePositivePositiveNegativePositive
C-34532.3PositivePositiveNegativeNegativePositive
S-26229.5PositivePositivePositivePositivePositive
S-16923.6PositivePositivePositiveNegativePositive
YOP HGE 02232.9PositivePositiveNegativeNegativePositive
H-356932.3PositivePositivePositiveNegativePositive
HGT HGE 01112,5PositivePositivePositiveNegativePositive
ETR 144B/181,3NegativeNegativePositivePositiveNegative

aRatio of the sample optical density (OD) to the threshold value (TV), as calculated by Monolisa AgHBs Ultra®. Samples with OD/TV values greater than or equal to 1.00 are considered reactive. b Determined with two EIA tests: Dia.Pro HBsAg® one version ULTRA for detection of HBsAg; positive samples were confirmed using Monolisa™ HBsAg ULTRA Confirmation test.