Study cohort median radiation exposure parameters and interquartile range (IQR) stratified by intervention type.

InterventionNAir Kerma (mGy) from both planesDAP (μGy m2) from both planesDAP/kg (μGy m2/kg) from both planesFluoroscopy time (min) from both planesFraction Air Kerma from fluoroscopy
MedianIQRMedianIQRMedianIQRMedianIQRMedianIQR

ASD closure582412–8322993–9909.05–23128–190.80.61–0.96
PDA closure1092717–4513575–253159–24139–190.50.35–0.59
Balloon dilation pulmonary valve452911–4711647–3262111–311610–210.40.2–0.52
Balloon dilation aortic valve256533–152394136–16013417–531512–280.40.15–0.46
Coarctation intervention4610134–386598176–26494522–901911–270.40.2–0.44
Transcatheter pulmonary valve17889539–142598696850–16616197153–2495130–620.50.26–0.68