Review Article
CT-IGFBP-4 as a Predictive Novel Biomarker of Ischemic Cardiovascular Events and Mortality: A Systematic Review
Table 3
Description of the assay used in CT-IGFBP-4 measurements in the included studies.
| S.N. | Author | Assay used for ct-igfbp-4 determination | Detection limit | Sample used | Storage |
| 1. | García-osuna [14] | ELISA (type not specified) | NR | EDTA-obtained plasma | −80°C |
| 2. | Schulz et al. [10] | Sandwich ELISA | 0.8 ng/ml | Lithium-heparin obtained plasma | −40°C |
| 3. | Konev et al. [11] | Sandwich ELISA using monoclonal antibodies (IBP163 as capture antibody, and IBP182HRP as detection antibody) | 0.15 ng/ml | Lithium-heparin obtained plasma | −80°C | Cross reactivity: <2% |
| 4. | Postnikov et al. [12] | Sandwich ELISA using monoclonal antibodies (IBP163 as capture antibody, and IBP182 as detection antibody) | 0.8 ng/ml | EDTA obtained plasma | −70°C | Cross-reactivity: <1.5% | Linearity range: 12–500 ng/mL |
| 5. | Hjortebjerg et al. [13] | Time-resolved-immunoflourimetric assay (TR-IFMA) using monoclonal antibodies IBP163 and IBP182 | 0.4 ng/ml | EDTA obtained plasma | NR |
|
|
ELISA, enzyme-linked immuno-sorbent assay. EDTA, ethylene diamine tetra-acetic acid. IBP, insulin binding protein. NR, not reported.
|