Research Article

Self-Expanding Versus Balloon Expanding Coronary Stents in Intervention of the Degenerated Saphenous Vein Graft: Memmingen Coronary Artery Bypass Stenosis Trial (MECAST)

Table 2

Procedural characteristics.

SExS (procedures = 61)BExS (procedures = 69) value
n SDn (%)n SDn (%)

DESFirst generation58.2000.516
Second generation5691.869100.0
Procedures per patient1.20.391.20.430.999
Stents per procedure1.40.441.40.290.999
EPD58.282.7411.60.521
Lesion preparationPre-dilatation615.69100515.5773.9<0.0001
Post-dilatation4675.42029.0<0.0001
Lesion locationOstial133.4221.3183.4926.10.462
Medial4573.83753.6
Distal31.714.9113.1715.9
Multiple00314.3
Low SVG score (0-1)4877.04663.80.30
TIMI pre-procedure031.714.957.20.979
131.714.900
272.5711.51014.5
3485.5078.7545.6278.3
TIMI post-procedure00011.001.40.742
10000
221.403.321.402.9
3595.6896.7665.7095.7
Procedural success611006898.60.317
Stent systemsOverall 85 (1.7 per patient) implanted stents;
STENTYS® (paclitaxel), STENTYS-SES® (sirolimus), Xposition S® (sirolimus)
Diameter range 2.5–4.5 mm
Length 17–37 mm
Overall 96 (1.8 per patient) implanted stents;
XIENCE®, promus element®, resolute integrety®, resolute Onyx®, Osiro®, BioMatrix®
Diameter range 2.25–5.0 mm
Length 8–32 mm

Values are number (n)standard deviation (SD), number (%) or meanstandard deviation. A value <0.05 is considered significant. SExS = self-expanding drug eluting stent; BExS = balloon expanding drug eluting stent; DES = drug eluting stent; EPD = embolic protection device; SVG = saphenous vein graft; TIMI = thrombolysis in myocardial infarction.