Research Article

Self-Expanding Versus Balloon Expanding Coronary Stents in Intervention of the Degenerated Saphenous Vein Graft: Memmingen Coronary Artery Bypass Stenosis Trial (MECAST)

Table 3

Outcome.

SExS (n = 51)BExS (n = 56) value
n SDn (%)n SDn (%)

MACE 30 days11.002.0712.50.039
MACE 12 months815.7204.0335.70.019
Cardiac death52.189.8712.50.660
MI11.002.0103.0117.90.007
TLR11.002.0113.1419.60.004
TVR35.9133.3823.20.012
Stent thrombosis (possible + definite)11.002.0712.50.039

Values are number (n)standard deviation (SD) or number (%). A value<0.05 is considered significant. SExS = self-expanding drug eluting stent; BExS = balloon expanding drug eluting stent; MACE = major adverse cardiac event; MI = myocardial infarction; TLR = target lesion revascularization; and TVR = target vessel revascularization.