Research Article
A New Statistical Approach Based on the Access of Electricity Application with Some Modified Control Charts
Table 7
Comparison of the
and
when
by using the EWMA control charts with
.
| Methods | Shifts | ARL | SDRL | | | | | |
| MLE | 0 | 200.367 | 198.1372 | 22.9 | 70 | 141 | 245 | 466.2 | 3.05 | 37.7055 | 37.42263 | 4 | 14 | 27 | 45 | 86 | 3.1 | 33.03 | 31.90847 | 4 | 12 | 23 | 40 | 72.1 | 3.2 | 26.1705 | 26.39126 | 3 | 9 | 18 | 31 | 61 | 3.4 | 15.2635 | 14.66512 | 2 | 6 | 11 | 18 | 35 | 3.6 | 10.083 | 9.665703 | 1 | 4 | 7 | 12 | 23 | 3.8 | 7.1215 | 7.006374 | 1 | 3 | 5 | 8 | 16 | 4 | 4.99 | 4.716887 | 1 | 2 | 4 | 6 | 11 | 4.2 | 3.6355 | 3.16317 | 1 | 1 | 3 | 4 | 8 | 4.4 | 2.9295 | 2.433617 | 1 | 1 | 2 | 3 | 6 | 4.6 | 2.3615 | 1.892249 | 1 | 1 | 2 | 3 | 5 |
| MMLE | 0 | 200.367 | 193.8012 | 21 | 72.7 | 139 | 246 | 462.1 | 2.5 | 1.5 | 0.917835 | 1 | 1 | 1 | 2 | 3 | 3.1 | 1.4725 | 0.866383 | 1 | 1 | 1 | 2 | 3 | 3.2 | 1.3995 | 0.772138 | 1 | 1 | 1 | 1 | 2 | 3.4 | 1.2715 | 0.599973 | 1 | 1 | 1 | 1 | 2 | 3.6 | 1.187 | 0.476597 | 1 | 1 | 1 | 1 | 2 | 3.8 | 1.143 | 0.40575 | 1 | 1 | 1 | 1 | 2 | 4 | 1.097 | 0.338598 | 1 | 1 | 1 | 1 | 1 | 4.2 | 1.0645 | 0.26339 | 1 | 1 | 1 | 1 | 1 | 4.4 | 1.0435 | 0.213613 | 1 | 1 | 1 | 1 | 1 | 4.6 | 1.028 | 0.17097 | 1 | 1 | 1 | 1 | 1 |
|
|