Research Article

Comparative Study of Structural, Electrical, and Magnetic Behaviour of Ni-Cu-Zn Nanoferrites Sintered by Microwave and Conventional Techniques

Table 2

Grain size, initial permeability, , and coercivity values of toroids.

Samples “Grain size (μm)Initial permeability at 10 kHz (Gauss)Coercivity (Oersted)
MWConMWConMWConMWCon

0.00.160.124.143.261441560.590.997
0.10.250.236.184.362871400.4040.510
0.20.400.3224.637.3411313825.6707.250
0.30.470.4531.549.7814155335.5848.625
0.40.370.3219.027.5510764037.1527.863
0.50.440.4224.618.5411564745.6368.738