Research Article

Electrical Impedance Measurements of PZT Nanofiber Sensors

Table 2

Estimated fractional power delivered to load from a generator having 50 TΩ DC source resistance.

InstrumentDC input impedance, (MΩ)Fractional power delivered,

Oscilloscope10.0000002
Lab amp1000.00002
Fabricated amp501