Research Article
IoT-Based Intelligent System for Internal Crack Detection in Building Blocks
Table 3
28-day cube strength and detected crack sizes.
| S. no. | Load in | 28-day cube compressive strength in N/mm2 | Cracks in mm |
| 1. | 50 | 2.22 | 0.00 | 2. | 100 | 4.42 | 0.00 | 3. | 150 | 6.67 | 0.05 | 4. | 200 | 8.89 | 0.10 | 5. | 250 | 11.11 | 0.10 | 6. | 300 | 13.33 | 0.15 | 7. | 350 | 15.56 | 0.18 | 8. | 400 | 17.78 | 0.26 | 9. | 450 | 20.00 | 0.30 | 10. | 500 | 22.22 | 0.53 | 11. | 550 | 24.44 | 1.05 | 12. | 600 | 26.67 | 1.53 | 13. | 643 | 28.58 | 1.85 |
|
|