Research Article
Nanosilica-Based Teff Straw as an Eco-Friendly Substitute for Special Concrete
Table 3
Test report on compressive strength and split tensile strength.
| Mix-code | Sample no. | Load failure for 150 mm size cubes (KN) | Concrete compressive strength (for 150 mm size cubes) (MPa) | Cylinder no. | Load failure (KN) | Tensile strength (splitting condition) (MPa) |
| M0 | 1 | 557.38 | 24.77 | 1 | 147.98 | 2.54 | 2 | 742.14 | 32.98 | 2 | 149.87 | 2.10 | 3 | 629.17 | 27.96 | 3 | 149.11 | 2.31 | Mean | 642.90 | 28.57 | Mean | 148.98 | 2.11 |
| M1 | 1 | 736.79 | 32.75 | 1 | 156.49 | 2.21 | 2 | 762.86 | 33.90 | 2 | 151.67 | 2.15 | 3 | 752.68 | 33.45 | 3 | 162.59 | 2.30 | | Mean | 750.75 | 33.37 | Mean | 156.92 | 2.22 |
| M2 | 1 | 587.23 | 26.10 | 1 | 135.46 | 1.92 | 2 | 515.64 | 22.92 | 2 | 159.78 | 2.26 | | 3 | 603.39 | 26.82 | 3 | 148.69 | 2.10 | Mean | 568.75 | 25.28 | Mean | 147.98 | 2.09 |
| M3 | 1 | 572.14 | 25.43 | 1 | 162.12 | 2.29 | 2 | 609.42 | 27.09 | 2 | 150.47 | 2.13 | 3 | 594.76 | 26.43 | 3 | 135.94 | 1.92 | Mean | 592.11 | 26.32 | Mean | 149.51 | 2.12 |
|
|