Research Article
Experimental Investigations on the Performance of Thermosyphon Solar Flat Plate Collector using TiO2 Nanofluids
Table 1
Specifications of solar flat plate collector.
| S. no. | Design materials/parameters | Specifications |
| Collector | 1 | Tilt angle | 10° (South facing) | 2 | Aperture area, Ac | 0.48 m2 | 3 | Collector glazing | Single transparent glass of 3 mm thickness | 4 | Riser tubes | OD 12.5 mm, ID 11 mm, length 2,000 mm | 5 | Absorber plate | Width 122 mm, length 2,000 mm | 8 | Bottom insulation | 100 mm glass wool | 9 | Side insulation | 60 mm glass wool covered by wooden frame | 10 | Absorber plate coating absorptivity | 0.92 | 11 | Transmittance of glazing | 0.91 | 12 | Number of riser tubes | 1 | Storage tank and piping | 13 | Tank type | Vertical | 14 | Tank volume | 10 l | 15 | Tank wall thickness | 4 mm | 16 | Tank insulation thickness | 50 mm | 17 | Connecting pipe size | ID 13 mm | 18 | Pipe insulation thickness | 20 mm |
|
|