Research Article

Clinical Value Analysis of Combined Vaginal Ultrasound, Magnetic Resonance Dispersion Weighted Imaging, and Multilayer Spiral CT in the Diagnosis of Endometrial Cancer Using Deep VGG-16 AdaBoost Hybrid Classifier

Table 2

Comparison of different algorithms for the experimental group.

AlgorithmAccuracy (%)Sensitivity (%)Specificity (%)Kappa coefficient (%)

FIGO [20]8889.0696.2568.9
Contrast enhanced ultrasonography (CEUS) [21]73879374.6
Transvaginal sonography [22]8689.890.976.6
DeepVGG-16 AdaBoost hybrid classifier (proposed)98.69197.881.5