Research Article

Assessment of Cone-Beam Breast Computed Tomography for Predicting Pathologic Response to Neoadjuvant Chemotherapy in Breast Cancer: A Prospective Study

Table 2

CBBCT parameters before and during NAC.

ParametersPre-NAC valueMid-NAC valueLate-NAC value

Lesion density/HU0.9990.6710.756
One-min enhancement/HU0.7940.1560.001
Two-min enhancement/HU0.8980.0070.001
Three-min enhancement/HU0.6210.0460.011
Diameter/mm0.0640.0060.012
Volume/mm20.0620.0020.017
Segmented volume/mm30.0820.004<0.001
Segmented surface area/mm20.0720.013<0.001
Washout rate (%/s)0.4220.0560.622
Maximum enhancement ratio (%)0.970.023<0.001
Wash-in rate (%/s)0.9210.034<0.001

Note: The numbers in the table represent mean with standard deviation. values with statistical value are marked with asterisk. HU: Hounsfield unit. CBBCT: Cone-beam breast computed tomography. NAC: Neoadjuvant chemotherapy.