Research Article

Accuracy of Intraocular Lens Power Formulas Involving 148 Eyes with Long Axial Lengths: A Retrospective Chart-Review Study

Table 1

Baseline characteristics of eyes included in the study.

AL (mm)Eyes (number)Patient age (yr)Mean AL (mm)Mean (D)

Group A
 26.01–27.002468.92 ± 10.1526.39 ± 0.3344.28 ± 1.92
 27.01–28.003367.67 ± 9.2427.46 ± 0.3244.06 ± 1.97
 Subtotal5768.19 ± 9.5627.01 ± 0.6344.15 ± 1.94
value0.015 /0.137
Group B
 28.01–29.001768.29 ± 11.8528.54 ± 0.2944.61 ± 1.84
 29.01–30.003166.58 ± 10.4529.49 ± 0.2444.39 ± 1.32
 Subtotal4867.19 ± 10.8729.16 ± 0.5344.47 ± 1.51
value0.029 /0.057
Group C
 30.01–31.001863.50 ± 10.5530.45 ± 0.3443.67 ± 1.70
 31.01–32.001364.92 ± 10.8931.45 ± 0.3044.17 ± 1.73
 32.01–33.00658.00 ± 9.8332.61 ± 0.2644.22 ± 0.86
 Subtotal3763.11 ± 10.4731.15 ± 0.8643.93 ± 1.59
value0.210/0.244
Group D
 33.01–36.00657.50 ± 4.6834.02 ± 1.0943.07 ± 0.58
 Subtotal657.50 ± 4.6834.02 ± 1.0943.07 ± 0.58

Total14866.16 ± 10.3729.03 ± 2.0544.15 ± 1.70
value0.017 /0.195

AL, axial length; , keratometric reading; D, diopters.
Compared with Group D (one-way ANOVA).
Compared among the four groups (one-way ANOVA).
indicates .