Clinical Study
Pupil Size Associated with the Largest Iris Volume in Normal Chinese Eyes
Table 3
Parameters at baseline and at one hour after induction of miosis (
).
| Variables | ME | FE | Baseline | After one hour | | Baseline | After one hour | |
| IOP (mmHg) | 15.21 ± 3.43 | 13.81 ± 3.31 | 0.003 | 15.00 ± 4.35 | 13.71 ± 3.60 | 0.018 | PS (mm) | 5.02 ± 0.92 | 3.08 ± 1.19 | 0.001 | 5.03 ± 0.87 | 4.37 ± 1.15 | 0.001 | ACV (mm3) | 152.69 ± 39.41 | 140.48 ± 35.24 | 0.001 | 149.63 ± 38.66 | 144.66 ± 37.32 | 0.023 | IV (mm3) | 26.21 ± 7.63 | 30.02 ± 4.40 | 0.002 | 26.79 ± 7.38 | 28.05 ± 1.21 | 0.112 | ACD (mm) | 2.86 ± 0.35 | 2.79 ± 0.34 | 0.001 | 2.84 ± 0.36 | 2.81 ± 0.39 | 0.134 |
|
|
ME: miosis-induced eye; FE: fellow eye; IV: iris volume.
|